Page 33 - Bendix Air disc brake-01
P. 33

12  Actuation cylinder replacement
                   (for “Axial- and Radial Disc Brake”)



               12.1  Brake Chamber removal

               Disconnect the air line from the Brake Chamber (18/2)

               Unscrew the Brake Chamber Mounting Nuts (do not
               re-use them).
                                                                                                       18/2
               Remove the Brake Chamber



                                                                                                          VF 00127/10
               12.2  Brake Chamber fitting

               IMPORTANT:
               New Brake Chambers (18/2) have drain plugs instal-
               led. Remove the bottom plug (see arrows). All other drain
               holes should be plugged.









                Before fitting the new Brake Actuator, the sealing
                surface of the Caliper (see arrow) must be cleaned, and
                the Spherical Cup (19) in the Lever must be greased
                with white Grease RENOLIT HLT2 (Order no II14525).

                The surface area of the flange must be clean.



                              IMPORTANT!


                   Do not use Grease containing molyb-
                    denum disulphate. Use only Bendix
                          Actuators recommended                             19
                        by the Vehicle Manufacturer.                                                 M+P-KN-034-Äi01






               Attach Actuator with new Nuts
               (self-locking EN ISO 7042) and torque tighten
                     +22          +30
               to 133  ft. lbs. (180   Nm).

               Connect the air hose and check for leakage.

               Make sure that the hose is not twisted and that chafing
               is not possible.



                              IMPORTANT!
               Road test vehicle before returning to service.
                   Test any air hoses or fittings removed
                 during maintenance work, using a soap
                 solution to check for leakage.  A 1 inch
                bubble in 1 minute is acceptable, otherwise
                repair/replace components as necessary.
                                                                                                             33

  SD-23-7550: 000: US: Released: Wed Apr 09 01:32:27 CEST 2014: